DESIGNING SOLUTIONS FOR NOW THAT ARE READY TO SHAPE THE FUTURE. THIS IS NEXXIS.
HomeKnowledge CentreProducts

SONOWALL 50

The light and compact ultrasonic wall thickness gauge SONOWALL 50 enables the precise measurement of the wall thickness of components made of metal, glass, ceramics and plastics.
Read More

This efficient device allows the measurement of materials with both flat and curved surfaces. The wall thickness gauge enables the quick and simple detection of the first signs of wear and corrosion, for example, on ships, storage tanks, pipelines and cranes etc.

The SONOWALL 50 is characterised by its stable data readout and broad measuring range. The integrated data logger makes this user-friendly device a powerful and efficient all-rounder for practical use in numerous applications. In addition to the robust aluminium housing and the use of the highest quality components and materials, the SONOWALL 50 also has a practical ergonomic design.

The SONOSCAN probe SW 5-22 for the SONOWALL 50 has been specifically designed for the measurement of wall thicknesses of pipes with small diameters. The integrated guidance system guarantees the stable coupling at curved pipe surfaces.

Advantages:

High precision measurement
Stable measurement data readout
Integrated data logger
Universal probe with a broad measuring range
Functional design of device and software

Applications:

Wallthickness measurement especially of pipes with small diameters

Contact us for more information on the SONOWALL 50 or any of our other thickness gauges, or request a quote online.

 

Specification
Application Wall thickness measurement gage
Measuring range 0,8 – 400 mm steel (dependent on probe type)
Sound velocity range 1.000 – 10.000 m/s
Probe frequencies 2 MHz, 5 MHz, special probes for pipes with small diameters (5 MHz), others upon request
Measurement resolution 0,01 mm (0,0001 inch)
Operating temperature -10 °C bis 50 °C
Storage temperature -20 °C bis 10 °C
Display Illuminated display (128 x 64 Pixel)
Test block Stainless steel (9 mm), integrated in housing
Connectors USB port for data logger, double Lemo 00 for probes
Power supply 2 x LR6 I AA – primary cells
Operating time 40 hours (backlight off)
Data loggers Max. 10.000 readings
Dimensions: L x W x H 128 x 80 x 28 mm
Weight 260 g
Protection Class Device: IP65, probe: IP67